Wooden door acceptance steps: careful inspection after installation

There are reflections from the attire, the new door in the house, and the buzzing sound of the switch is very irritating. But to find businesses, people simply do not admit it. Although the importance of the door is getting lower and lower, but it is not good, but it will seriously affect the quality of life of the family, but the average consumer can still master certain skills, the first inspection after installation.

Maxim wooden door ace wooden door

After determining the size of the door opening, professionals at the wooden door manufacturer or decoration company will determine the size of the door. Some door openings that cannot be changed in size require custom doors. According to experts, the openings of some load-bearing walls, such as walls that were originally brick structures or reinforced concrete structures, could not be changed from small to large. These openings can only be customized. When manufacturers measure, wall thickness, ground height, etc. are generally measured.

By the time the door is delivered, because the wooden doors are all in good condition, the consumer can first look at the outer packaging and have no damage. If there is, there is a possibility that there are internal injuries. In addition, you can also check whether the specifications, size, shape and color of the door are consistent with the agreement. However, when looking at colors, consumers do not need to change the door as soon as they find the color difference. In general, there are some color differences between solid wood doors and solid wood composite doors. However, experts advise consumers that there is a chromatic aberration when opening the package. It may be an illusion that all the doors and sets must be installed and then observed. If it is true that there is a color difference between a part and the whole, it is of course possible to require the manufacturer to replace it.

In addition, consumers can ask manufacturers for a product specification. The content of the manual should include basic information on the material, process, environmental performance, and physical properties of the wooden door; the national requirements for the specification of materials and processes; the introduction of the company's wooden door manufacturing process; the national quality standards and related technical specifications of the wooden door; Wooden door installation procedures and precautions. With this specification, even if consumers are laymen, they can understand and know many things. In addition, this specification is also a detailed description of the wooden door. Once a problem arises, it can also be used as a proof of consumer rights protection in the future.

With conditions to install

The wooden door is a kind of installation project and can be synchronized with installation projects such as sanitary ware and cabinets. According to experts, after the wooden doors are installed in the middle of the project, they are generally completed after large-scale construction projects. Specifically, walls, floor tiles, and floors have been paved, and the putty on the walls has been scraped twice. After it has been brushed once. "Even if there are bumps during the installation of the wooden door, you can use the last time the paint to make up for it."

In addition, the code stipulates that in rooms with relatively high humidity such as kitchens, bathrooms, basements, etc., the door covers must not be in direct contact with the ground. It is necessary to leave 2-3 mm of space, and then seal the glass glue to prevent the products from being deformed by moisture. The set of wires fixed on the sleeve plate should be as close to the wall as possible. Because the wall is not vertical or the thickness is uneven, the door line and the wall have gaps, and the gap needs to be sealed with a sealant. Experts remind consumers that if the wall is affixed with wallpaper, they must choose neutral glue rather than ordinary glue. Apply waterproof glue evenly on the parts of the door line and the wall surface, so that the door line and the wall can be firmly combined. If the waterproof glue is exposed, it should be removed in time. In addition, "the kitchen bathroom door backs need to do waterproof anti-corrosion treatment, to avoid the water vapor absorbed by the door line after the discoloration occurs, the paint peel off mold mold deformation."

During the installation process, consumers will also have some misunderstandings. For example, in the gap between the door panel and the wall, foam rubber is generally used. Many consumers think that they should play tight and fill all gaps. However, experts said that in fact, as long as the actual situation can be, and usually need a 5 cm gap, in order to facilitate the longitudinal expansion of the foam and ventilation curing. Due to the elasticity and plasticity of the foam rubber, if it is played too tightly, the door cover will be pushed out and it will not adhere tightly to the wall. The door cover will be curved and the door will not close.

Multi-party check to do a good job acceptance

If possible, you can find a connoisseur to help with the acceptance. Ordinary consumers can also accept the wooden door from the following aspects. Whether the opening and closing are normal, there is no gap between the tongue and the locking piece, and the outer surface is intact and not damaged. The most important thing is whether the door is horizontal or vertical. In general, the horizontal and vertical door, open to a place, where the door stops, will not automatically close or open. A convenient way to see if the door is horizontal and vertical is to observe whether the worker installs the wooden door using an infrared level meter to repeatedly calibrate the door and the cover.

In addition, pay attention to the distance between the doors. In general, the gap between the door and the ground must be between 5-8mm, and the gap between the left and right of the door and the gap between the walls should not exceed 6mm. Otherwise, the door will not open when the temperature difference changes; in addition, the upper edge of the door Cannot exceed 2mm.

You can also check if the opening direction of the door is reasonable. Take the entrance door as an example. If the living room is on the left hand side, then the door should open to the right, which is in line with people's living habits.

Links: Long-lasting floors like maintenance tips for new floors

Doors Doors Doors Doors Doors Doors Doors Doors Doors Flooring Glass Doors Kitchen Doors Doors Flooring Glass Doors Glass Doors Doors Doors Doors Doors Doors Doors Doors Doors Toilets Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Baths