UV Explosion-Proof Flame Detector

Model NO.: BK53Ex/UV
Trademark: GQ
Specification: GB
Origin: China
Model NO.: BK53Ex/UV
Trademark: GQ
Specification: GB
Origin: China
Explosion Proof Flame Detector-UV
UV Explosion-Proof Flame Detector
Application scope

JTGB-HZW-BK53Ex/UV point type UV flame detector (hereinafter called detector)  shell by integration of the mould die casting. Its technical parameter fully satisfy the codes of (China National Standard) GB3836.1-2000 , GB3836.2-2000 and GB4208-93 requirements on explosion-proof, its explosion-proof mark is ExdIICT6. It suitable for factory. The temperature group is T1~T6 group. Which can detect the fire in danger places.
 
Main purpose and scope of application
Detector is suitable for various industries, such as all kinds of oil depots, wine storage, chemical libraries, ammunition depot, aircraft library, liquefied gas station, large power plants) and in the civil building no smoldering stage on fire, suddenly caught fire places.
1. Aerospace - hydroxide, hydrazine and hydrogen fuel, aircraft
2. Chemicals - production, storage, transport
3. Power generation --- pump area, computer room, no inspecting area
4. Explosives and munitions - storage and handling
5. Printing, Solvent processing, pressing and drying process
6. Rubber industry - manufacturing and synthesis
7. Automotive - manufacturing, spray paint room
8. Warehouses - storage of flammable materials
9. Petrochemical products - production, storage and transportation
10. Pharmaceutical industry
 
Products characteristic
  1. The ultraviolet (UV) spectrum detection
  2. High grade on explosion-proof, dust-proof
  3. With wide temperature range operation
  4. 120 degree wide cone shape region detection
  5. Real-time self diagnosis function
  6. The electromagnetic radiation immunity
  7. The patent, industrial design
  8. The sensitivity is adjustable.
  9. Standard 4-20mA output current, standard RS-485 interface, passive contact output
 
Using environmental conditions
Elevation low than 1500m;
Ambient temperature:-10ºC ~ +55ºC
Ambient air relative humidity less than 95% (40 + 2ºC)
Be used as a fire detector in maybe explosion hazard site

Working principle
 
The UV flame detector equipped with a high sensitive UV sensor, which monitors the early flame UV radiation. The unique UV flame sensor can detect ultraviolet radiation in the light of fire and explosion at same time. Special circuit design can satisfy variety of environmental and technical requirements. The special logic circuit can prevent the false alarming caused by solar radiation. Ultraviolet flame detector is especially used to detect the invisible flame: hydrogen, silane, ammonia, hydride and metal fire. It suitable the flame precise detection in industrial environment. It can work stable in high / low temperature, high humidity, vibration and other harsh environment.
 
Inspecting area

Inspecting area: 3D conical view as shown below.
Detector can detect the fire following square inverse law: if the inspecting distance doubled, then there is only 1/4 radiation could reach the detector.
For example: the UV flame detector can detect 0.1 m2 (33cm × 33cm) ethanol fire in distance of 17 meters, if the detector be installed in detecting distance of 34 meters, the minimum could be detected fire need 0.4 m2. On the contrary, within the 8.5 meters range, only 0.025 m2 fire will be able to activate alarm.
UV Explosion-Proof Flame Detector

Flame detector's detecting distance
 
The flame detector's detecting distance is related to the size of the flame radiation produced by the different combustion objects and the flame size is expected to occur in the early stage of the fire. In the case of long distance, it is related to the ultraviolet radiation is absorbed.

A. China National Code GB 12791-2005 defined two standard test fires:

0.1m2heptane plus 3% (volume percent) toluene fire

0.1m2 ethanol fire

B. China National Code GB 12791-2005 defined three sensitivity levels:

Within the scope of 0 ~ 25 meters range, detector must report the 1st degree fire alarm.

Within the scope of 0 ~ 17 meters range, detector must report the 2nd degree fire alarm.

Within the scope of 0 ~ 12 meters range, detector must report the 3rd degree fire alarm.


The correction coefficient of the combustion detection distance on different combustion objects as following:
combustion object Ethanol gasoline diesel kerosene (aviation oil) methanol crude oil acetone
correction coefficient 1.0 1.5 0.8 1.0 0.8 1.0 1.5
For example, if gasoline is the target to be detected, the maximum detection distance is 1.5 times of ethanol.
 
Technical characteristics
Main parameter
 
Basic technical parameters
Spectral response: 185 ~ 260nmUV
Fire response time: <30S
Monitoring angle:<=120ºC
Ambient temperature:  -40ºC to 70 ºC
Ambient humidity: < 95% RH (40ºC+2ºC)
Detect distance: 15 meters (0.1 M2 gasoline)
 
Electrical parameters
Working voltage: DC 18V~32V
Indicating light: normal is flashing. Alarm will keep lighting.
Working current: standby state <= 20mA (DC 24V)
Alarm state <= 35mA (DC 24V)
 
Output mode: relay output
Normal state: the fault relay contact is closed, the fire alarm relay contact is open
Fault state: the fault relay contacts from closed to open.
Fire alarm state: the fire alarm relay contact changed to closed.
Relay contact capacity: 0.5A/AC 125V, 1A /DC 30V,  0.3A/ DC 60V
4mA~20mA output: fault 0+0.5mA, normal 5 mA + 10%,  fire alarm 18mA ± 10%
RS-485 output: equipped with RS-485 standard interface, which can be used to connect the controller and other equipments
 
Authentication:
Explosion proof mark: ExdIICT6
Dust explosion proof mark: DIP A21, TA, T6
Inspection: Satisfy the China National Code GB12791-2005
Protection level: IP65
Execution standard: GB12791-2005, GB3836.1-2000, GB3836.2-2000, GB12476.1-2000


UV Explosion-Proof Flame DetectorUV Explosion-Proof Flame DetectorUV Explosion-Proof Flame Detector
Explosion Proof Flame Detector-UV
UV Explosion-Proof Flame Detector
Application scope

JTGB-HZW-BK53Ex/UV point type UV flame detector (hereinafter called detector)  shell by integration of the mould die casting. Its technical parameter fully satisfy the codes of (China National Standard) GB3836.1-2000 , GB3836.2-2000 and GB4208-93 requirements on explosion-proof, its explosion-proof mark is ExdIICT6. It suitable for factory. The temperature group is T1~T6 group. Which can detect the fire in danger places.
 
Main purpose and scope of application
Detector is suitable for various industries, such as all kinds of oil depots, wine storage, chemical libraries, ammunition depot, aircraft library, liquefied gas station, large power plants) and in the civil building no smoldering stage on fire, suddenly caught fire places.
1. Aerospace - hydroxide, hydrazine and hydrogen fuel, aircraft
2. Chemicals - production, storage, transport
3. Power generation --- pump area, computer room, no inspecting area
4. Explosives and munitions - storage and handling
5. Printing, Solvent processing, pressing and drying process
6. Rubber industry - manufacturing and synthesis
7. Automotive - manufacturing, spray paint room
8. Warehouses - storage of flammable materials
9. Petrochemical products - production, storage and transportation
10. Pharmaceutical industry
 
Products characteristic
  1. The ultraviolet (UV) spectrum detection
  2. High grade on explosion-proof, dust-proof
  3. With wide temperature range operation
  4. 120 degree wide cone shape region detection
  5. Real-time self diagnosis function
  6. The electromagnetic radiation immunity
  7. The patent, industrial design
  8. The sensitivity is adjustable.
  9. Standard 4-20mA output current, standard RS-485 interface, passive contact output
 
Using environmental conditions
Elevation low than 1500m;
Ambient temperature:-10ºC ~ +55ºC
Ambient air relative humidity less than 95% (40 + 2ºC)
Be used as a fire detector in maybe explosion hazard site

Working principle
 
The UV flame detector equipped with a high sensitive UV sensor, which monitors the early flame UV radiation. The unique UV flame sensor can detect ultraviolet radiation in the light of fire and explosion at same time. Special circuit design can satisfy variety of environmental and technical requirements. The special logic circuit can prevent the false alarming caused by solar radiation. Ultraviolet flame detector is especially used to detect the invisible flame: hydrogen, silane, ammonia, hydride and metal fire. It suitable the flame precise detection in industrial environment. It can work stable in high / low temperature, high humidity, vibration and other harsh environment.
 
Inspecting area

Inspecting area: 3D conical view as shown below.
Detector can detect the fire following square inverse law: if the inspecting distance doubled, then there is only 1/4 radiation could reach the detector.
For example: the UV flame detector can detect 0.1 m2 (33cm × 33cm) ethanol fire in distance of 17 meters, if the detector be installed in detecting distance of 34 meters, the minimum could be detected fire need 0.4 m2. On the contrary, within the 8.5 meters range, only 0.025 m2 fire will be able to activate alarm.
UV Explosion-Proof Flame Detector

Flame detector's detecting distance
 
The flame detector's detecting distance is related to the size of the flame radiation produced by the different combustion objects and the flame size is expected to occur in the early stage of the fire. In the case of long distance, it is related to the ultraviolet radiation is absorbed.

A. China National Code GB 12791-2005 defined two standard test fires:

0.1m2heptane plus 3% (volume percent) toluene fire

0.1m2 ethanol fire

B. China National Code GB 12791-2005 defined three sensitivity levels:

Within the scope of 0 ~ 25 meters range, detector must report the 1st degree fire alarm.

Within the scope of 0 ~ 17 meters range, detector must report the 2nd degree fire alarm.

Within the scope of 0 ~ 12 meters range, detector must report the 3rd degree fire alarm.


The correction coefficient of the combustion detection distance on different combustion objects as following:
combustion object Ethanol gasoline diesel kerosene (aviation oil) methanol crude oil acetone
correction coefficient 1.0 1.5 0.8 1.0 0.8 1.0 1.5
For example, if gasoline is the target to be detected, the maximum detection distance is 1.5 times of ethanol.
 
Technical characteristics
Main parameter
 
Basic technical parameters
Spectral response: 185 ~ 260nmUV
Fire response time: <30S
Monitoring angle:<=120ºC
Ambient temperature:  -40ºC to 70 ºC
Ambient humidity: < 95% RH (40ºC+2ºC)
Detect distance: 15 meters (0.1 M2 gasoline)
 
Electrical parameters
Working voltage: DC 18V~32V
Indicating light: normal is flashing. Alarm will keep lighting.
Working current: standby state <= 20mA (DC 24V)
Alarm state <= 35mA (DC 24V)
 
Output mode: relay output
Normal state: the fault relay contact is closed, the fire alarm relay contact is open
Fault state: the fault relay contacts from closed to open.
Fire alarm state: the fire alarm relay contact changed to closed.
Relay contact capacity: 0.5A/AC 125V, 1A /DC 30V,  0.3A/ DC 60V
4mA~20mA output: fault 0+0.5mA, normal 5 mA + 10%,  fire alarm 18mA ± 10%
RS-485 output: equipped with RS-485 standard interface, which can be used to connect the controller and other equipments
 
Authentication:
Explosion proof mark: ExdIICT6
Dust explosion proof mark: DIP A21, TA, T6
Inspection: Satisfy the China National Code GB12791-2005
Protection level: IP65
Execution standard: GB12791-2005, GB3836.1-2000, GB3836.2-2000, GB12476.1-2000


UV Explosion-Proof Flame DetectorUV Explosion-Proof Flame DetectorUV Explosion-Proof Flame Detector

Step Lights

LEDER technology`s step light illuminates at night and solar power charges the lights during the day. The step light will light up your patio, walkway, deck, and stairs for extra safety with bright LED.

This Solar Powered Battery Powered Deck Light Pack is weatherproof stainless steel rechargeable solar step lights that feature ultra-bright surface mount LED and a high-performance solar panel. Plus the built-in light sensor automatically turns this light on at night and the frosted front plate evenly disperses light so you can see in the dark. Never worry about tripping over wires, cords, or replacing dead batteries again. Simply mount this light horizontally against any flat surface using the provided installation accessories and enjoy over 8 hours of light every night! Each package includes 2 LED lights, mounting screws, fasteners, and installed solar rechargeable batteries.

Features:

• Solar Charging Technology

• Made of stainless steel

• reduced design

• Energy saving save electricity

• Color temperature :3000k-6000K

• Auto-induction

• Type of protection: IP20 /IP65 (Some models)

• Warranty:3 - 5 years

Allowing you to perfectly illuminate your deck, stairs, walkway, or dock. Plus this light is made of weather resistant solid stainless steel for year round use.

We have rich production experience in lighting .Except Step Light , we also offered other product in Outdoor Lighting ,such as LED Flood Light , LED street Light , LED Inground Light, LED Spike Light & LED Bollard Light as so on .


Stair Lights,LED Stair Lights,Stair Lights Indoor,Solar Step Lights

LEDER LIGHTING CO.,LTD , https://www.lederlight.com